UK Stair Regulations (Approved Document K)

A planning check against Approved Document K, 2013 edition, for use in England: rise, going, private-stair pitch, and twice rise plus going. This page is not a translation of the US IRC, and it does not apply to Scotland, Wales, or Northern Ireland automatically.

Check rise, going and pitch

Enter the total rise of the flight and the going of each step. Leave the riser count blank to use the smallest number that keeps each rise at or under the Table 1.1 maximum for the category you choose. Results update as you type. Units default to millimetres.

Approved Document K Table 1.1 — rise and going

Paragraph 1.3 says to use any rise between the minimum and maximum with any going between the minimum and maximum that complies with the relevant note in the table. Measure rise and going as in Diagram 1.1: going is nosing to nosing. Paragraph 1.5 requires the rise and going of each step to be consistent throughout the flight.

Category Rise (mm) Going (mm) Notes printed with Table 1.1
Private stair150–220220–300Maximum pitch 42° (note 1). For dwellings, external tapered steps and stairs that are part of the building should have a going of at least 280 mm (note 2).
Utility stair150–190250–400—
General access stair150–170250–400For school buildings, the preferred going is 280 mm and rise is 150 mm (note 3).

The table’s footnote describes the normal relationship between rise R and going G as 550 mm ≤ (2R + G) ≤ 700 mm. The tool reports that value and flags when it falls outside that band, separately from the mandatory-looking ranges and the 42° private-stair pitch note.

Pitch is arctan(rise ÷ going). A private stair cannot always use the maximum rise with the minimum going: 220 mm rise and 220 mm going is 45°, which is steeper than note 1. For a 220 mm going, a 42° pitch allows a rise of at most about 198.1 mm (220 × tan 42°).

The default example is a 2600 mm total rise and a 220 mm going on a private stair. Twelve risers give a 216.67 mm rise, which is inside 150–220 mm, but the pitch is about 44.56° — over 42°. Increasing the going to 250 mm on the same 12 risers brings the pitch to about 40.93° and 2R + G to about 683 mm, inside the normal 550–700 mm relationship.

Other Approved Document K figures often asked about

TopicGuidance in the 2013 edition (England)Where
HeadroomAt least 2 m on the access between levels, as in Diagram 1.3; 2 m clear on means-of-escape routes in buildings other than dwellings and in common areas of flats, except in doorways. Reduced headroom for loft conversions is shown in Diagram 1.4 (1.9 m / 1.8 m as drawn).1.11–1.13
Handrail heightTop of the handrail 900–1000 mm from the pitch line or floor; the handrail may form the top of a guarding if the heights can be matched. Stairs 1000 mm or wider should have a handrail on both sides.1.34
When a dwelling flight needs handrails in a special caseIn the exceptional sloping-plot case described in paragraph 1.37, a flight of three or more risers in the entrance storey should have a suitable continuous handrail on each side of the flight and any intermediate landings.1.37
Guarding of flights in dwellingsProvide guarding at the sides of flights and landings when there is a drop of more than 600 mm.1.41
Guarding height, single-family dwellingsDiagram 3.1: 900 mm for stairs, landings, ramps, and edges of internal floors; 1100 mm for external balconies, including Juliette balconies, and edges of roof.Diagram 3.1, 1.38, 3.2
Open risers in dwellingsAllowed if treads overlap by at least 16 mm and a 100 mm sphere cannot pass through.1.9

Approved Document K does not set a single private-stair width for every dwelling flight; width in dwellings is also covered in Approved Document M. Paragraph 1.16’s 900 mm figure applies only to the exceptional entrance-storey stepped change it describes. This page does not invent a general UK width or a US-style 36 in / 7¾ in limit.

Staircase building regulations is a search phrase that often means this Approved Document K guidance in England. Always confirm the document that applies at the address, including any local or devolved rules, and treat this as a planning check rather than a building-control decision.

Sources

Disclaimer: These pages are planning tools and code-chart extracts only. They are not a substitute for the adopted building code, a local amendment, a permit review, or a licensed designer or engineer. The International Residential Code is a model code: it has legal force only where a jurisdiction adopts it, and many places amend individual limits. Approved Document K is guidance for meeting the Building Regulations in England; other UK nations use different documents. Stair Deck Reference does not inspect sites, approve drawings, or sign off construction.